ABC Cable, Aerial Bundled Cable, 0.6/1 Kv (NF C 33-209) From Luxing Cable Factory
1.1kv,10kvinsulated overhead line
This product is suitable for AC rated voltage (Uo / U) 1/10kv power distribution grid system.
1kv insulated overhead line adopt GB/T12527-2008 & GB/T1179-2008 standard.
10kv insulated overhead line adopt GB/T14049-2008 & GB/T1179-2008 standard.
ABC Cable, Aerial Bundled Cable, 0.6/1 KV (NF C 33-209) from luxing cable factory
1.1kv,10kvinsulated overhead line This product is suitable for AC rated voltage (Uo / U) 1/10kv power distribution grid system. 1kv insulated overhead line adopt GB/T12527-2008 & GB/T1179-2008 standard. 10kv insulated overhead line adopt GB/T14049-2008 & GB/T1179-2008 standard.
2.Type, name,laying occasion
Type
Laying occasion
Copper core
Aluminum core
Steel core(intensive)aluminum stranded core
JKV
JKLV(BLVW)
JKLGV(BLVWG or BLGVW)
Aerial fixed laying lines or service wire,only for 0.6/1kv line.
JKYJ
JKLYJ
JKLGYJ
Aerial fixed laying lines,cables and trees should be set up to consider keeping a certain distance,during cable working,it is allowed to contact frequent with trees.
JKYJ/Q
JKLYJ/Q
JKLGYJ/Q
Aerial fixed laying lines,cables and trees should be set up to consider keeping a certain distance,during cable working,it is allowed to contact temporary with trees.
JKYJ/J
JKLYJ/J
JKLGYJ/J
Aerial fixed laying lines,cables and trees should be set up to consider keeping a certain distance,during cable working,it is allowed to contact frequent with trees,allow low laying.
3.Operating characteristic
1)rated voltage 0.6/1kv,10kv 2)max permissible continuous operating temperature of conductor:PVC insulated ≤70ºC.XLPE insulated ≤90ºC. 3)during short circuit(lasting less than 5s),the maximum temperature of the cable:PVC insulated is 160ºC;XLPE insulated should not exceed 250ºC. 4)laying temperature of cable should not less than -20ºC,cable should be preheated when below -20ºC. 5)bending radius: -0.6/1kv D<25mm,should not less than 4D;steel core( intensive) should not less than 6D. D≥25mm,should not less than 6D;steel core(intensive) should not less than 10D. -10kv single core cable should not less than 20D,steel core strand should not less than 25D. multi-core cable should not less than 15D,steel core strand should not less 20D.
4.Why buy cables from luxing cable factory?
1) Reliable material; -Each raw material into the plant, must undergo a rigorous selection and testing, -To ensure that the best material to you. 2) Strict production; -24 production processes, 24 detection processes, -Each of the strict control procedures to ensure cable safety.
3) Safe packaging ; -Using wood fumigation plate, plus metal packaging, -reliable transport so that cable safely arrived at your site.