1.KVVP Cable with PVC Insulation and Sheath
Plastic insulated control cable are used for connecting electrical equipments. It applies to controlling, monitoring and protective system with A.C. rated voltage U0/U up to and including 450/750V
![]() | ![]() |
2.Working Condition
1)Long term working temperature of conductor allowed by cable is 70ºC.
2)Environment temperature for installation is no less than 0ºC.
3)Min. bending radius of cable is no less than 6 times that of cable OD for cable without armoring, 12 times for cable with armoring or metallic tape shielding and 6 times for soft cable with shielding structure.
3.Cable structrue:
![]() | ![]() |
1.Conductor
2.Conductor screen (no light type)
3.Filler
4.Wrapping tape
5.Copper tape screen
6.Sheath
7.Extruded or lapped bedding
8.Double steel tape armour
4.Standards
It is manufactured in accordance with GB/T9330-2008, and the factory can also manufacture the cables in accordance with other standards such as IEC, BS, DIN, etc.
![]() | ![]() |
5.Cable Type and Name
Type | Name |
KVV | Copper conductor PVC insulated PVC sheathed control cable |
KVVP2 | Copper conductor PVC insulated PVC sheathed copper tape screened control cable |
KVV22 | Copper conductor PVC insulated PVC sheathed steel tape armored control cable |
KVVP2-22 | Copper conductor PVC insulated PVC sheathed copper tape screened, steel tape armored control cable |
KVVR | Copper conductor PVC insulated PVC sheathed control flexible cable |
KVV32 | Copper conductor PVC insulated PVC sheathed steel wire armored control cable |
KVVP2-32 | Copper conductor PVC insulated PVC sheathed copper tape screened steel wire armored control cable |
KYJV | Copper conductor XLPE insulated PVC sheathed control cable |
KYJVP2 | Copper conductor XLPE insulated PVC sheathed copper tape screened control cable |
KYJV22 | Copper conductor XLPE insulated PVC sheathed steel tape armored control cable |
KYJVP2-22 | Copper conductor XLPE insulated PVC sheathed copper tape screened steel tape armored control cable |
KYJV32 | Copper conductor XLPE insulated PVC sheathed steel wire armored control cable |
KYJVP2-32 | Copper conductor XLPE insulated PVC sheathed copper tape screened steel wire armored control cable |
6.Main Technical Parameter
Number of cores x Nominal cross-section mm2 | Kind of | Reference outside diameter of cable mm | Reference weight of cable kg/km | Max.D.C. resistance at 20ºC | Min.insulation resistance |
2 x 0.75 | 1 | 7.2 | 61 | 24.5 | 0.012 |
2 x 0.75 | 2 | 7.5 | 65 | 24.5 | 0.014 |
2 x 2.5 | 1 | 9.6 | 124 | 7.41 | 0.01 |
2 x 2.5 | 2 | 10.2 | 135 | 7.41 | 0.01 |
2 x 10 | 2 | 15.7 | 377 | 1.83 | 0.0065 |
5 x 0.75 | 1 | 8.7 | 101 | 24.5 | 0.012 |
5 x 0.75 | 2 | 9.1 | 108 | 24.5 | 0.014 |
5 x 2.5 | 1 | 12.7 | 247 | 7.41 | 0.01 |
5 x 2.5 | 2 | 13.4 | 267 | 7.41 | 0.01 |
5 x 10 | 2 | 20.4 | 769 | 1.83 | 0.0065 |
10 x 0.75 | 1 | 11.6 | 176 | 24.5 | 0.012 |
10 x 0.75 | 2 | 12.2 | 189 | 24.5 | 0.014 |
10 x 2.5 | 1 | 17.2 | 447 | 7.41 | 0.01 |
10 x 2.5 | 2 | 18.2 | 483 | 7.41 | 0.01 |
10 x 10 | 2 | 28.4 | 1452 | 1.83 | 0.0065 |
30 x 0.75 | 1 | 17.6 | 450 | 24.5 | 0.012 |
30 x 0.75 | 2 | 18.6 | 483 | 24.5 | 0.014 |
30 x 2.5 | 1 | 26 | 1167 | 7.41 | 0.01 |
30 x 2.5 | 2 | 27.6 | 1262 | 7.41 | 0.01 |
61 x 0.75 | 1 | 23.8 | 857 | 24.5 | 0.012 |
61 x 0.75 | 2 | 25.1 | 906 | 24.5 | 0.014 |
61 x 2.5 | 1 | 36 | 2320 | 7.41 | 0.01 |
61 x 2.5 | 2 | 38.3 | 2509 | 7.41 | 0.01 |