Construction :
Conductor: H03VV-F/ H05VV-F Bare copper fine wire or Copper Clad Aluminum Wire(CCA Wire)(stranded) class5 acc.to IEC60228
Insulation:PVC Compound
Sheath:PVC Compound
Sheath Color:White ,Black,Grey
Techical Data :
Standard:IEC 60227-5 / VDE 0281/NFC-32-201
Fixed installed: -30ºC up to +70ºC
At short circuit of max.5s up to 160ºC
Nominal Voltage: : H03VV-F 300/300V
H05VV-F 300/500V
Min inner bending radius:4D for D<8mm
5D for D=12mm
6D for D>12mm
Behaviour in fire:
Flame retardant cable acc.to IEC60332-1
Application:
Flexible cable(H03VV-F/ H05VV-F) for medium mechanical stresses. Permitted frequent bending and twisting. Specially suitable for application in household, kitchens and offices in dry and damp conditions, for inst. washing-machines, dryers, refrigerators etc., as long as the cable is adapted to essential specifications of the device. Also suitable for cookers, i.e. hot devices, on condition that it does not get in direct contact with hot parts of the device and is not exposed to heat irradiation. Suitable for fixed installation in furniture, partition walls, decorative linings and cavities in prefabricated construction elements.
Size Techical Parameter:
No.of cores xNominal section area | Nominal Construction of conductor | Nominal Insulation thickness | Nominal Sheath thickness | Nominal Overall diameter | Nominal Cable weight | Max.Resistance of conductor at 20ºC |
No.Xmm² | No.X mm | mm | mm | mm | kg/km | <=(Ω/km) |
5 x 0,75 | 24 x 0,20 | 0,6 | 0,8 | 8.6 | 112 | 26,0 |
5 x 1,0 | 32 x 0,20 | 0,6 | 0,8 | 10.3 | 158 | 19,5 |
5 x 1,5 | 30 x 0,25 | 0,7 | 0,9 | 10.9 | 190 | 13,3 |
5 x 2,5 | 50 x 0,25 | 0,8 | 1 | 12.6 | 272 | 7,98 |
5 x 4 | 56 x 0,30 | 0,8 | 1 | 14.2 | 377 | 4,95 |
5 x 6 | 84 x 0,30 | 0,8 | 1 | 16.4 | 527 | 3,30 |
5x 10 | 80 x 0,40 | 1,0 | 1,2 | 20.5 | 852 | 1,91 |
5 x 16 | 128 x 0,40 | 1,0 | 1,2 | 24.4 | 1276 | 1,21 |
5x 25 | 200 x 0,40 | 1,2 | 1,4 | 31.2 | 2044 | 0,780 |
5 x 35 | 280 x 0,40 | 1,2 | 1,4 | 37.2 | 2885 | 0,554 |
Model | Conductor | insulation Thickness | jacket Thickness | Average overall diameter | Max. conductor Resistance | Min. Insulation Resistance | ||
(at 20) | (at 70) | |||||||
Nominal area | construction | Lower limit | Upper limit | copper | ||||
mm2 | No./ mm | mm | mm | mm | mm | Ω/km | kΩ km | |
H05VV-F | 2*0.75 | 24/0.20 | 0.6 | 0.8 | 5.7 | 7.2 | 26 | 0.011 |
H05VVH2-F | 2*0.75 | 24/0.20 | 0.6 | 0.8 | 3.7*6.0 | 4.5*7.2 | 26 | 0.011 |
H05VV-F | 2*1 | 32/0.20 | 0.6 | 0.8 | 5.9 | 7.5 | 19.5 | 0.01 |
H05VVH2-F | 2*1 | 30/0.25 | 0.6 | 0.8 | 3.9*6.2 | 4.7*7.5 | 19.5 | 0.01 |
H05VV | 2*1.5 | 49/0.25 | 0.7 | 0.8 | 6.8 | 8.6 | 13.3 | 0.01 |
H05VV | 2*2.5 | 56/0.30 | 0.8 | 1 | 8.4 | 10.6 | 7.98 | 0.009 |
H05VV | 2*4 | 24/0.20 | 0.8 | 1.1 | 9.7 | 12.1 | 4.95 | 0.007 |
H05VV | 3G0.75 | 24/0.20 | 0.6 | 0.8 | 6 | 7.6 | 26 | 0.011 |
H05VV | 3G1 | 32/0.20 | 0.6 | 0.8 | 6.3 | 8 | 19.5 | 0.01 |
H05VV | 3G1.5 | 30/0.25 | 0.7 | 0.9 | 7.4 | 9.4 | 13.3 | 0.01 |
H05VV | 3G2.5 | 49/0.25 | 0.8 | 1.1 | 9.2 | 11.4 | 7.98 | 0.009 |
Exhibition:
Certificates
Packaging & Shipping
All cable For exporting are well packed and protected by wooden drum or Wood and Steel Drum.
The packing material is depended on the weight and size of cable.
The good information, manufacture information, and the client's information is firmly printed on each size of drum.
After the well packed cable drums sent to Sea Port, they are loaded into 20 FT container or 40 FT container. All cable drum are firmly fixed by safety belt to make sure, no movement during the sea freight.
The size of the container is chosed according to weight of total loaded goods or as per the client's requirement.