1.Product description:
(1) Conductor: Pure Copper/ CCA
(2) Type of the conductor: Solid/Stranded
(3) Insulation: PVC
(4) Normal of area: (1/2/3/4/5)x (1.0mm2 - 70mm2)
(5) Voltage: 300/500V 450/750V 600/1000V
(6) Core color: Red, brown, green, yellow/green, black, blue, yellow, etc.
(7) Standard: BS6004
(8) Code name: BVV
2.Application:
Suitable for surface wiring, indoor or outdoor.
4.Technical Data:BVV
Core number* nominal cross section mm2 | Conductor type | Rated value of sheath thickness mm | Rated value of sheath thickness mm | Upper Value of average overall diameter mm | Minimum insulation resistance under temperature 700C MΩ.km |
2×1.5 | 1 | 0.7 | 1.2 | 10.0 | 0.011 |
2 | 0.7 | 1.2 | 10.5 | 0.010 | |
2×2.5 | 1 | 0.8 | 1.2 | 11.5 | 0.010 |
2 | 0.8 | 1.2 | 12.0 | 0.009 | |
2×4 | 1 | 0.8 | 1.2 | 12.5 | 0.0085 |
2 | 0.8 | 1.2 | 13.0 | 0.0077 | |
2×6 | 1 | 0.8 | 1.2 | 13.5 | 0.0070 |
2 | 0.8 | 1.2 | 14.0 | 0.0065 | |
2×10 | 1 | 1.0 | 1.4 | 16.5 | 0.0070 |
2 | 1.0 | 1.4 | 17.5 | 0.0065 | |
2×16 | 2 | 1.0 | 1.4 | 20.0 | 0.0052 |
2×25 | 2 | 1.2 | 1.4 | 24.0 | 0.0050 |
2×35 | 2 | 1.2 | 1.6 | 27.5 | 0.0044 |
3×1.5 | 1 | 0.7 | 1.2 | 10.5 | 0.011 |
2 | 0.7 | 1.2 | 11.0 | 0.010 | |
3×2.5 | 1 | 0.8 | 1.2 | 12.0 | 0.010 |
2 | 0.8 | 1.2 | 12.5 | 0.009 | |
3×4 | 1 | 0.8 | 1.2 | 13.0 | 0.0085 |
2 | 0.8 | 1.2 | 13.5 | 0.0077 | |
3×6 | 1 | 0.8 | 1.4 | 14.5 | 0.0070 |
2 | 0.8 | 1.4 | 15.5 | 0.0065 | |
3×10 | 1 | 1.0 | 1.4 | 17.5 | 0.0070 |
2 | 1.0 | 1.4 | 19.5 | 0.0065 | |
3×16 | 2 | 1.0 | 1.4 | 21.5 | 0.0052 |
3×25 | 2 | 1.2 | 1.4 | 26.0 | 0.0050 |
3×35 | 2 | 1.2 | 1.6 | 29.0 | 0.0044 |
4×1.5 | 1 | 0.7 | 1.2 | 11.5 | 0.011 |
2 | 0.7 | 1.2 | 12.0 | 0.010 | |
4×2.5 | 1 | 0.8 | 1.2 | 13.0 | 0.010 |
2 | 0.8 | 1.2 | 13.5 | 0.009 | |
4×4 | 1 | 0.8 | 1.4 | 14.5 | 0.0085 |
2 | 0.8 | 1.4 | 15.0 | 0.0077 | |
4×6 | 1 | 0.8 | 1.4 | 16.0 | 0.0070 |
2 | 0.8 | 1.4 | 17.0 | 0.0065 | |
4×10 | 1 | 1.0 | 1.4 | 19.0 | 0.0070 |
2 | 1.0 | 1.4 | 20.5 | 0.0065 | |
4×16 | 2 | 1.0 | 1.4 | 23.5 | 0.0052 |
4×25 | 2 | 1.2 | 1.6 | 27.5 | 0.0050 |
4×35 | 2 | 1.2 | 1.6 | 32.0 | 0.0044 |
5×1.5 | 1 | 0.7 | 1.2 | 12.0 | 0.011 |
2 | 0.7 | 1.2 | 12.5 | 0.010 | |
5×2.5 | 1 | 0.8 | 1.2 | 14.0 | 0.010 |
2 | 0.8 | 1.2 | 14.5 | 0.009 | |
5×4 | 1 | 0.8 | 1.4 | 16.0 | 0.0085 |
2 | 0.8 | 1.4 | 17.0 | 0.0077 | |
5×6 | 1 | 0.8 | 1.4 | 17.5 | 0.0070 |
2 | 0.8 | 1.4 | 18.5 | 0.0065 | |
5×10 | 1 | 1.0 | 1.4 | 21.0 | 0.0070 |
2 | 1.0 | 1.4 | 22.0 | 0.0065 | |
5×16 | 2 | 1.0 | 1.6 | 26.0 | 0.0052 |
5×25 | 2 | 1.2 | 1.6 | 31.5 | 0.0050 |
5×35 | 2 | 1.2 | 1.6 | 35.0 | 0.0044 |
Note: 1.Conductor structure is selected according to GB/T3956.Type 1 is adopted as solid core conductor and type 2 is adopted as stranded conductor.
2.Insulator:PVC/C type PVC mixture is adopted as insulating material.
3.Sheath:PVC/ST4 model PVC mixture should be adopted as the inner sheath.
4.The average overall diameter should be within the limitation stipulation of the table.
Application
Widely used in electronics, instruments, electronic equipment and automatic generation of devices in the power cord, the line of control and signal transmission lines. Concretely can be used for anti-theft alarm system, building intercom system, household lighting cables and so on.
Exhibition:
Certificates
Packaging & Shipping
All cable For exporting are well packed and protected by wooden drum or Wood and Steel Drum.
The packing material is depended on the weight and size of cable.
The good information, manufacture information, and the client's information is firmly printed on each size of drum.
After the well packed cable drums sent to Sea Port, they are loaded into 20 FT container or 40 FT container. All cable drum are firmly fixed by safety belt to make sure, no movement during the sea freight.
The size of the container is chosed according to weight of total loaded goods or as per the client's requirement.