Flexible Cable(CU/PVC/PVC, Flexible copper conductor, PVC insulated,PVC sheathed.)
Cable Type | Cable structure | Cable Pictures |
NYAF,300/500V | Flexible copper conductor, PVC insulated. | ![]() |
NYMHY cable, HO5VVF cable, H07VVF cable, NYY cable. | Flexible copper conductor, PVC insulated, PVC sheathed. | ![]() |
1.Applications:
1)Power cord or internal wiring with low mechanical stress for electrical equipments, machineries, luminaires and other portable appliances.
2)Permanent exposed wiring in humid environment, installation in tray or under plaster for general purpose 220-240 VAC single phase domestical
application, inherently flame retardant in compliance with IEC60332-1.
2.Cable specification.
Cores x Cross section area | Insulation thickness | Sheath thickness | External diameter | Conductor resistance at 20 °C | resistance of insulation at 70 °C |
nominal | nominal | min-max. | max. | min. | |
mm² | mm | mm | mm | Ω/km | MΩkm |
2X0.75 | 0.6 | 0.8 | 5.7-7.2 (3.7X6.0-4.5 X7.2) | 26 | 0.011 |
2X1 | 0.6 | 0.8 | 5.9-7.5 (3.9X6.2-4.7 X7.5) | 19.5 | 0.010 |
2X1.5 | 0.7 | 0.8 | 6.8-8.6 | 13.3 | 0.010 |
2X2.5 | 0.8 | 1.0 | 8.4-10.6 | 1.98 | 0.009 |
2X4 | 0.8 | 1.1 | 9.7-12.1 | 4.95 | 0.007 |
3X0.75 | 0.6 | 0.8 | 6.0-7.6 | 26 | 0.011 |
3X1 | 0.6 | 0.8 | 6.3-8.0 | 19.5 | 0.010 |
3X1.5 | 0.7 | 0.9 | 7.4-9.4 | 13.3 | 0.010 |
3X2.5 | 0.8 | 1.1 | 9.2-11.4 | 1.98 | 0.009 |
3X4 | 0.8 | 1.2 | 10.5-13.1 | 4.95 | 0.007 |
4X0.75 | 0.6 | 0.8 | 6.6-8.3 | 26 | 0.011 |
4X1 | 0.6 | 0.8 | 7.1-9.0 | 19.5 | 0.010 |
4X1.5 | 0.7 | 1.0 | 8.4-10.5 | 13.3 | 0.010 |
4X2.5 | 0.8 | 1.1 | 10.1-12.5 | 1.98 | 0.009 |
4X4 | 0.8 | 1.2 | 11.5-14.3 | 4.95 | 0.007 |
5X0.75 | 0.6 | 0.9 | 7.4-9.3 | 26 | 0.011 |
5X1 | 0.6 | 0.9 | 7.8-9.8 | 19.5 | 0.010 |
5X1.5 | 0.7 | 1.1 | 9.3-11.6 | 13.3 | 0.010 |
5X2.5 | 0.8 | 1.2 | 11.2-13.9 | 1.98 | 0.009 |
5X4 | 0.8 | 1.4 | 13.0-16.1 | 4.95 | 0.007 |
7X1 | 0.6 | 1.0 | 9.3-12.0 | 19.5 | 0.010 |
7X1.5 | 0.7 | 1.2 | 11.0-14.0 | 13.3 | 0.010 |
7X2.5 | 0.8 | 1.2 | 13.0-17.0 | 1.98 | 0.009 |
3.The advantage of Luxing factory
1)Reliable material ;
-Each raw material into the plant, must undergo a rigorous selection and testing,
-To ensure that the best material to you.
2)Strict production;
-24 production processes, 24 detection processes,
-Each of the strict control procedures to ensure cable safety.
3) Safe packaging;
-Using wood fumigation plate, plus metal packaging,
-reliable transport so that cable safely arrived at your site.
4.Certificates
5.Test report.