Zhfr Insulated Non Sheathed Single Core Cables For Internal Wiring

Conductor:Stranded bare copper or tinned copper
Insulation:PVC
Chat Now

Product Details

1.Application:

1Type  TW THW THHN THWN TFF building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)Type  TW THW THHN THWN TFF is permitted for new construction or rewiring for 60volt applications. Applications requiring Type THHN or THWN2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.
Features:
Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.
Jacket:
A tough, polyamide, Nylon outer covering per UL-1063 and UL-83.


2.Standard:UL-83, UL-1063, UL-758
BS Standard Solid Stranded Conductor Resistant Heat BVV Bvr BV Thw Thwn Thhn House Building Overhead Flexible Insulating Sheath PVC Copper Cable Electric Wire

3.Specification:
UL 83 UL 1581

AWG/MCMmm2ConductorInsulationShealthTotal Weight
Single WireOD.PVCNylon
No.Dia.thickminminOD.Thick milsmmOD.



mmmmmilmmmmmilmmmmmilmmmmkg/km
161.3111.291.29150.380.51140.362.0540.12.2516.73
142.0811.6261.626150.380.51140.362.38640.12.58624.53
123.2912.0482.048150.380.51140.362.80840.13.00836.61
105.2612.5892.589200.510.64190.483.60940.13.80958
161.6770.5511.653150.380.51140.362.41340.12.61321.5
142.0870.6151.845150.380.51140.362.60540.12.80525.84
123.3070.7752.325150.380.51140.363.08540.13.28538.51
105.2670.9782.934200.510.64190.483.95440.14.15460.82
96.6371.0983.294200.510.64190.484.31450.134.57475.34
88.3271.233.69300.760.9280.715.2150.135.4798.69
710.4771.384.14300.760.9280.715.6650.135.92120.76
613.2171.554.65300.760.9280.716.1750.136.43148.58
516.6571.745.22300.760.9280.716.7460.157.04183.78
421.1271.965.88401.021.1350.897.9260.158.22235.76
233.5472.477.41401.021.1350.899.4560.159.75359.83
161.23190.2871.435150.380.51140.362.19540.12.39516.72
142.04190.371.85150.380.51140.362.6140.12.8125.35
123.30190.472.35150.380.51140.363.1140.13.3138.27
105.19190.592.95200.510.64190.483.9740.14.1759.86
96.50190.663.3200.510.64190.484.3250.134.5873.64
88.17190.743.7300.760.9280.715.2250.135.4895.16
710.53190.844.2300.760.9280.715.7250.135.98120.74
613.19190.944.7300.760.9280.716.2250.136.48145.02
516.45191.055.25300.760.9280.716.7760.157.07180.78
421.13191.195.74401.021.1350.897.7860.158.08229.38
326.40191.336.45401.021.1350.898.4960.158.79280.88
233.58191.57.26401.021.1350.899.360.159.6350.23
142.12191.688.15501.271.38451.1410.6970.1811.05447.22
1/053.30191.899.14501.271.38451.1411.6870.1812.04555.15
2/067.07192.1210.3501.271.38451.1412.8470.1813.2687.52
3/084.53192.3811.6501.271.38451.1414.1470.1814.5854.27
4/0107.18192.6813501.271.38451.1415.5470.1815.91068.65
250125.72372.0814.2601.521.67551.417.2480.217.641272.29
300151.06372.2815.5601.521.67551.418.5480.218.941512.81
350177.29372.4716.8601.521.67551.419.8480.220.241761.4
400202.53372.6417.9601.521.67551.420.9480.221.341999.42
500252.89372.9519.7601.521.67551.422.7480.223.142470.99
600304.24612.5222701.781.94651.6525.5690.2326.022998.91
650328.87612.6222.9701.781.94651.6526.4690.2326.923231.59
750378.30612.8124.6701.781.94651.6528.1690.2328.623697.59
1000506.04613.2528.4701.781.94651.6531.9690.2332.424896.32


4.Other UL specification:
TW THW

TW THW
600V 60ºC
UL 83 UL 1581
Type TW and THW may be used for general purpose wiring for power and
lighting, for insulation in air, conduit, duct or other recognized raceways, in wet or dry locations.
Maximum voltage rating= 600 V
MAXIMUM CONDUCTOR TEMPERATURE
typeoilwetdry
TW60ºC60ºC60ºC
THW75ºC75ºC75ºC
MTW*60ºC60ºC90ºC
* 1AWG AND LARGER ONLY

 

AWG/MCMmm2ConductorConductorInsulationTotal Weight
TypeSingle WireOD.PVCkg/km

No.Dia.ThickmmThickminOD.

mils
180.82solid11.021.02300.760.890.72.5414.82
161.31solid11.291.29300.760.890.72.8120.27
142.09solid11.631.63300.760.890.73.1528.6
123.33solid12.062.06300.760.890.73.5841.48
105.27solid12.592.59300.760.890.74.1160.93
88.35solid13.263.26451.141.2215.5498.99
613.33solid14.124.12601.521.671.47.16162.23
421.16solid15.195.19601.521.671.48.23240.34
180.82B70.3861.158300.760.890.72.67815.65
161.31B70.4881.464300.760.890.72.98421.43
142.08B70.6151.845300.760.890.73.36530.1
123.30B70.7752.325300.760.890.73.84543.38
105.26B70.9782.934300.760.890.74.45464.02
88.32B71.233.69451.141.2215.97103.92
613.21B71.554.65601.521.671.47.69169.62
421.12B71.965.88601.521.671.48.92252.44
233.54B72.477.41601.521.671.410.45379.53
142.62B191.698.18802.032.111.812.24480.75
1/053.30B191.899.19802.032.111.813.25586.71
2/067.70B192.1310.34802.032.111.814.4727.52
3/085.24B192.3911.61802.032.111.815.67897.84
4/0107.18B192.6813801.521.671.416.441097.15
250126.94B372.0914.2952.412.562.219.021340.08
300152.39B372.2915.54952.412.562.220.361586.07
350177.29B372.4716.79952.412.562.221.611825.98
400202.53B372.6417.96952.412.562.222.782068.12
500252.89B372.9520.04952.412.562.224.862548.31
600304.24B612.52221102.792.892.527.583084.92
750380.99B612.8224.641102.792.892.530.223816.9
1000506.04B613.2528.41102.792.892.533.985002.6

Products Show

BV, Blv, BVV, Blvv, BVVB, Blvvb, Bvr Electric Wires

Exhibition:

Electric Cable CCA Conductor BV WireElectric Cable CCA Conductor BV Wire

Certificates

Wholesale PVC Insulated Electrical Cable Wire 3.5mm
Packaging & Shipping

All cable For exporting are well packed and protected by wooden drum or Wood and Steel Drum.

The packing material is depended on the weight and size of cable.

The good information, manufacture information, and the client's information is firmly printed on each size of drum.


After the well packed cable drums sent to Sea Port, they are loaded into 20 FT container or 40 FT container. All cable drum are firmly fixed by safety belt to make sure, no movement during the sea freight.

The size of the container is chosed according to weight of total loaded goods or as per the client's requirement.

2104

Hot Tags: zhfr insulated non sheathed single core cables for internal wiring, China, manufacturers, suppliers, factory

Inquiry

You Might Also Like