300 Mm2 XLPE Low Voltage Power Cable

Conductor:Copper
Insulation:PVC/XLPE
Outer Sheath:PVC or PE
Chat Now

Product Details

Low Price China Factory Manufacture 300mm2 xlpe cable Low Voltage XLPE Power Cable

Product Description

Product Description Of Low Voltage XLPE Power Cable

Product standard:

GB/T12706.1-2008

Application:

This product is suitable for power transmission and distribution line of rated voltage (U0/U) 0.6/1.0KV line.

Technical Parameter:

When the cable is running normally, the Maximum temperature of conductor is 90ºC; and is 250 ºC when the short circuit (Max. last 5s) happens.

The ambient temperature of installation shall not lower than 0 degrees.

Minimum bending radius is 12 D ("D" refers to cable diameter)

Single Core Cable

Nominal cross sectionNominal Thickness of InsulationNominal thickness of SheathApprox. Overall Diameter of CableApproximate weight of cableConductor DC resistanceTest voltageCable Current
In the airBuried in soil
CuALCuALCuALCuAL
mm²mmmmmmKg/kmKg/kmΩ/kmΩ/kmkv/5minAAAA
1*1.50.71.565353≤12.1≤12.13.526263332
1*2.50.71.5668
≤7.413.53443
1*40.71.578764≤4.61≤7.413.544355642
1*60.71.5711073≤3.08≤4.613.556457054

Two Cores Cable

Nominal cross sectionNominal Thickness of InsulationNominal thickness of SheathApprox. Overall Diameter of CableApproximate weight of cableConductor DC resistanceTest voltageCable Current
In the airBuried in soil
CuALCuALCuALCuAL
mm²mmmmmmKg/kmKg/kmΩ/kmΩ/kmkv/5minAAAA
2*2.50.71.811.8151118≤7.41≤12.13.526203527
2*40.71.812.7198146≤4.61≤7.413.534274536
2*60.71.813.7250173≤3.08≤4.613.543355746
2*100.71.816.3374245≤1.83≤3.083.560477759

Three Cores Cable

Nominal cross sectionNominal Thickness of InsulationNominal thickness of SheathApprox. Overall Diameter of CableApproximate weight of cableConductor DC resistanceTest voltageCable Current
In the airBuried in soil
CuALCuALCuALCuAL
mm²mmmmmmKg/kmKg/kmΩ/kmΩ/kmkv/5minAAAA
3×1.50.71.510145-≤12.1-3.520-27-
3×1.60.71.511185140≤7.41≤12.13.526203527
3×40.71.512250175≤4.61≤7.413.534274536
3×60.71.513320210≤3.08≤4.613.543355746
3×100.71.515450260≤1.83≤3.083.560477759

Four Cores Cable

Nominal cross sectionNominal Thickness of InsulationNominal thickness of SheathApprox. Overall Diameter of CableApproximate weight of cableConductor DC resistanceTest voltageCable Current
In the airBuried in soil
CuALCuALCuALCuAL
mm²mmmmmmKg/kmKg/kmΩ/kmΩ/kmkv/5minAAAA
4×40.71.513253155≤4.61≤7.413.534274536
4×60.71.514337184≤3.08≤4.613.543355746
4×100.71.516501258≤1.83≤3.083.560477759

Three Cores+One Core Cable

Nominal cross sectionNominal Thickness of InsulationNominal thickness of SheathApprox. Overall Diameter of CableApproximate weight of cableConductor DC resistanceTest voltageCable Current
In the airBuried in soil
CuALCuALCuALCuAL
mm²mmmmmmKg/kmKg/kmΩ/kmΩ/kmkv/5minAAAA
3×4+1×2.50.71.513236147≤4.61≤7.413.534274536
3×6+1×40.71.514316187≤3.08≤4.613.543355746
3×10+1×60.71.516461234≤1.83≤3.083.560477759

Three Cores+Two Cores Cable

Nominal cross sectionNominal Thickness of InsulationNominal thickness of SheathApprox. Overall Diameter of CableApproximate weight of cableConductor DC resistanceTest voltageCable Current
In the airBuried in soil
CuALCuALCuALCuAL
mm²mmmmmmKg/kmKg/kmΩ/kmΩ/kmkv/5minAAAA
3×4+2×2.50.71.513.9309202≤4.61≤7.413.534274536
3×6+2×40.71.515.3413219≤3.08≤4.613.543355746
3×10+2×60.71.518.2603338≤1.83≤3.083.560477759

Four Cores+One Core Cable

Nominal cross sectionNominal Thickness of InsulationNominal thickness of SheathApprox. Overall Diameter of CableApproximate weight of cableConductor DC resistanceTest voltageCable Current
In the airBuried in soil
CuALCuALCuALCuAL
mm²mmmmmmKg/kmKg/kmΩ/kmΩ/kmkv/5minAAAA
4×4+1×2.50.71.514.5331214≤4.61≤7.413.534274536
4×6+1×40.71.515.9435259≤3.08≤4.613.543355746
4×10+1×60.71.518.9649359≤1.83≤3.083.560477759

Five Cores Cable

Nominal cross sectionNominal Thickness of InsulationNominal thickness of SheathApprox. Overall Diameter of CableApproximate weight of cableConductor DC resistanceTest voltageCable Current
In the airBuried in soil
CuALCuALCuALCuAL
mm²mmmmmmKg/kmKg/kmΩ/kmΩ/kmkv/5minAAAA
5×40.71.514.5349223≤4.61≤7.413.534274536
5×60.71.515.8460271≤3.08≤4.613.543355746
5×100.71.519.3699384≤1.83≤3.083.560477759

Products Show

300 mm2 XLPE Low Voltage Power Cable


Exhibition:

PVC Insulated Function 50mm2 25mm Low Voltage 3 Core Electric CablePVC Insulated Function 50mm2 25mm Low Voltage 3 Core Electric Cable

Certificates

PVC Insulated Function 50mm2 25mm Low Voltage 3 Core Electric Cable
Packaging & Shipping

All cable For exporting are well packed and protected by wooden drum or Wood and Steel Drum.The packing material is depended on the weight and size of cable.The good information, manufacture information, and the client's information is firmly printed on each size of drum.

After the well packed cable drums sent to Sea Port, they are loaded into 20 FT container or 40 FT container. All cable drum are firmly fixed by safety belt to make sure, no movement during the sea freight.

The size of the container is chosed according to weight of total loaded goods or as per the client's requirement.

PVC Insulated Function 50mm2 25mm Low Voltage 3 Core Electric Cable

Shipping Terms

DHL, UPS,FEDEX, TNT, or designated forwarder.

Payment Terms

T/T, Western Union, or PayPal

Freight cost

Prepay with goods payment or pay by collected.

Packaging

Packed in bulk or as request

Carton Measure

49*33*23.5cm, 33*30*15cm, 30*30*18cm

PVC Insulated Function 50mm2 25mm Low Voltage 3 Core Electric Cable
 


Hot Tags: 300 mm2 xlpe low voltage power cable, China, manufacturers, suppliers, factory