600/1000V IEC Standard PVC Insulated Power Cable

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
Chat Now

Product Details

600/1000V IEC Standard PVC Insulated Power Cable

600/1000V IEC Standard PVC Insulated Power Cable600/1000V IEC Standard PVC Insulated Power Cable600/1000V IEC Standard PVC Insulated Power Cable


1.Applications
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors,
in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants,
where there is no risk of mechanical damage.
600/1000V IEC Standard PVC Insulated Power Cable


2.Construction
600/1000V IEC Standard PVC Insulated Power Cable


-Conductors
The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy,
or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.


-Insulation
PVC Insulation material and thickness shall be as per IEC 60502-1, PVC material shall be Type A as per IEC 60502-1.

-Colour Code
  Colour Code (1)

1 CoreRed or Black
2 CoresRed, Black
3 CoresRed, Yellow, Blue
4 CoresRed, Yellow, Blue, Black
5 CoresRed, Yellow, Blue, Black, Green
Above 5 CoresBlack Cores with White numerals

Colour Code (2)

1 CoreBrown or Blue
2 CoresBrown, Blue
3 CoresBrown, Black, Grey
4 CoresBlue, Brown, Black, Grey
5 CoresGreen/Yellow, Blue, Brown, Black, Grey
Above 5 CoresBlack Cores with White numerals

Other colours can be manufactured upon request.

-Assembly / Inner Covering

The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores,
a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled.
A suitable binder is permitted before application of an extruded inner covering.
The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the
insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.

-Armour
Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1,
or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
-Outer Sheath
Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8,
Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
-Fire Performance of Cable Sheaths

Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22,
IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

3.Parameters

Single core(unarmoured)
 

Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation ThicknessNominal Sheath ThicknessOverall Diameter (Approx.)
mm^2mmmmmmmm
1x42.311.47.1
1x62.811.47.6
1x103.611.48.4
1x164.511.49.3
1x255.61.21.410.8
1x356.71.21.411.9
1x5081.41.413.6
1x709.41.41.415.1
1x95111.61.517.2
1x12012.41.61.518.7
1x15013.81.81.620.6
1x18515.321.722.7
1x24017.52.21.825.4
1x30019.52.41.928.0
1x40022.62.62.031.7
1x50025.22.82.135.0
1x63028.32.82.238.3

 

Two cores(unarmoured)

Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation ThicknessNominal Sheath ThicknessOverall Diameter (Approx.)
mm^2mmmmmmmm
2x1.51.40.81.89.6
2x2.51.80.81.810.4
2x42.311.812.2
2x62.811.813.2
2x103.611.814.8
2x164.511.816.6
2x255.61.21.819.6
2x356.71.21.821.8
2x5081.41.825.2
2x709.41.41.928.1
2x95111.62.032.4
2x12012.41.62.135.4
2x15013.81.82.239.2
2x18515.322.443.3
2x24017.52.22.548.9
2x30019.52.42.754.0
2x40022.62.62.961.5




Three cores(unarmoured)


Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation ThicknessNominal Sheath ThicknessOverall Diameter (Approx.)
mm^2mmmmmmmm
3x1.51.40.81.810.1
3x2.51.80.81.810.9
3x42.311.812.9
3x62.811.813.9
3x103.611.815.7
3x164.511.817.6
3x255.61.21.820.8
3x356.71.21.823.2
3x5081.41.826.9
3x709.41.41.930.1
3x95111.62.134.7
3x12012.41.62.238.0
3x15013.81.82.342.1
3x18515.322.546.5
3x24017.52.22.752.5
3x30019.52.42.858.0
3x40022.62.63.166.1


Three cores+1(unarmoured)

Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation ThicknessNominal Sheath ThicknessOverall Diameter (Approx.)
mm^2(3)mm(1)mm(3)mm(1)mmmmmm
3x 16/104.53.6111.819.0
3x 25/165.64.51.211.822.6
3x 35/166.74.51.211.825.3
3x 50/258.05.61.41.21.929.6
3x 70/359.46.71.41.22.033.2
3x 95/5011.08.01.61.42.238.4
3x120/7012.49.41.61.42.342.0
3x150/7013.89.41.81.42.546.6
3x185/9515.311.021.62.651.6
3x240/12017.512.42.21.62.958.3
3x300/15019.513.82.41.83.164.5
3x400/18522.615.32.623.373



Four cores(unarmored)

Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation ThicknessNominal Sheath ThicknessOverall Diameter (Approx.)
mm^2mmmmmmmm
4x1.51.40.81.810.8
4x2.51.80.81.811.8
4x42.311.814.0
4x62.811.815.2
4x103.611.817.1
4x164.511.819.3
4x255.61.21.822.9
4x356.71.21.825.6
4x5081.41.929.9
4x709.41.42.033.5
4x95111.62.238.7
4x12012.41.62.342.3
4x15013.81.82.546.9
4x18515.322.651.9
4x24017.52.22.958.6
4x30019.52.43.164.8
4x40022.62.63.373.8


Multi-cores(unarmoured)

Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation ThicknessNominal Sheath ThicknessOverall Diameter (Approx.)
mm^2mmmmmmmm
5x1.51.40.81.811.7
7x1.51.40.81.812.6
10x1.51.40.81.815.6
12x1.51.40.81.816.1
14x1.51.40.81.816.8
19x1.51.40.81.818.6
21x1.51.40.81.819.5
24x1.51.40.81.821.6
30x1.51.40.81.822.8
40x1.51.40.81.827.7
48x1.51.40.81.928.2
61x1.51.40.81.930.9
5x2.51.80.81.812.8
7x2.51.80.81.813.8
10x2.51.80.81.817.2
12x2.51.80.81.817.7
14x2.51.80.81.818.6
19x2.51.80.81.820.6
21x2.51.80.81.821.6
24x2.51.80.81.824.0
30x2.51.80.81.825.4
40x2.51.80.82.031.1
48x2.51.80.82.031.7
61x2.51.80.82.134.7



Single core( aluminum wire armoured)

Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation thicknessNominal Inner Covering thicknessNominal Steel Wire dia.Nominal Sheath thicknessOverall Diameter (Approx.)
mm^2mmmmmmmmmmmm
1x42.311.00.81.811.5
1x62.811.00.81.812.0
1x103.611.00.81.812.8
1x164.511.00.81.813.7
1x255.61.21.00.81.815.2
1x356.71.21.01.251.817.2
1x508.01.41.01.251.818.9
1x709.41.41.01.251.820.3
1x9511.01.61.01.61.823.0
1x12012.41.61.01.61.824.4
1x15013.81.81.01.61.826.2
1x18515.321.01.61.928.2
1x24017.52.21.01.61.931.0
1x30019.52.41.02.02.134.4
1x40022.62.61.22.02.238.6
1x50025.22.81.22.02.341.8
1x63028.32.81.22.52.446.2



Two cores(Galvanized steel wire armoured)

Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation thicknessNominal Inner Covering thicknessNominal Steel Wire dia.Nominal Sheath thicknessOverall Diameter (Approx.)
mm^2mmmmmmmmmmmm
2x2.51.80.81.00.81.814.0
2x42.311.01.251.816.7
2x62.811.01.251.817.7
2x103.611.01.251.819.3
2x164.511.01.251.821.1
2x255.61.21.01.61.824.8
2x356.71.21.01.61.827.0
2x5081.41.01.61.930.7
2x709.41.41.02.02.134.5
2x95111.61.22.02.239.2
2x12012.41.61.22.02.342.2
2x15013.81.81.22.52.547.2
2x18515.321.42.52.651.6
2x24017.52.21.42.52.857.2
2x30019.52.41.62.53.062.8
2x40022.62.61.62.53.270.3



Thr cores(Galvanized steel wire armoured)

Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation thicknessNominal Inner Covering thicknessNominal Steel Wire dia.Nominal Sheath thicknessOverall Diameter (Approx.)
mm^2mmmmmmmmmmmm
3x2.51.80.81.00.81.814.5
3x42.311.01.251.817.4
3x62.811.01.251.818.4
3x103.611.01.251.820.2
3x164.511.01.61.822.8
3x255.61.21.01.61.826.0
3x356.71.21.01.61.928.5
3x508.01.41.022.033.3
3x709.41.41.222.137.0
3x9511.01.61.222.341.6
3x12012.41.61.22.52.445.9
3x15013.81.81.42.52.650.4
3x18515.321.42.52.754.8
3x24017.52.21.52.52.961.2
3x30019.52.41.62.53.166.8
3x40022.62.81.63.153.476.7
3x50025.22.81.83.153.783.6


Three cores+1(Galvanized steel wire armoured)

Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation thicknessNominal Inner Covering thicknessNominal Steel Wire dia.Nominal Sheath thicknessOverall Diameter (Approx.)
mm^2mmmmmmmmmmmmmmmm
3x10/63.62.81111.251.821.9
3x16/104.53.61111.61.824.2
3x25/165.64.51.2111.61.827.9
3x35/166.74.51.2111.61.930.8
3x50/258.05.61.41.212.02.036.4
3x70/359.46.71.41.21.22.02.140.1
3x95/5011.08.01.61.41.22.52.346.3
3x120/7012.49.41.61.41.42.52.450.3
3x150/7013.89.41.81.41.42.52.655.0
3x185/9515.311.021.61.42.52.760.3
3x240/12017.512.42.21.61.62.52.967.0
3x300/15019.513.82.41.81.63.153.174.6
3x400/18522.615.32.621.83.153.484.1
3x500/24025.217.52.82.223.153.791


Four cores(Galvanized steel wire armoured)

Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation thicknessNominal Inner Covering thicknessNominal Steel Wire dia.Nominal Sheath thicknessOverall Diameter (Approx.)
mm^2mmmmmmmmmmmm
4x42.3111.251.818.5
4x62.8111.251.819.7
4x103.6111.251.822.3
4x164.5111.61.824.5
4x255.61.211.61.928.2
4x356.71.211.62.031.1
4x508.01.412.02.136.7
4x709.41.41.22.02.340.4
4x9511.01.61.22.52.546.6
4x12012.41.61.42.52.650.6
4x15013.81.81.42.52.755.3
4x18515.321.42.52.960.6
4x24017.52.21.62.53.167.3
4x30019.52.41.63.153.474.9
4x40022.62.61.83.153.784.4
4x50025.22.823.153.992.1


Hot Tags: 600/1000v iec standard pvc insulated power cable, China, manufacturers, suppliers, factory

Inquiry

You Might Also Like