We can customize various types of cable in accordance with your requirements
XLPE /PVC insulated power cable
Mode and name
Power cable
Model | Name |
YJV YJLV | CU or AL conductor ,XLPE/pvc insulated PVC sheathed electric cable |
YJV22 YJLV32 | Cu or Al conductor XLPE /pvc insulated steel tape armoured ,steel wire armor pvc sheathed electric cable |
We can produce 1kv up to 35kv power cable
XLPE insulated power cable 0.6/1kv | |||||||||||
norminalsectional area | insulati-on thicknes | sheath thickness(mm) | overal diameter of cable (mm) | D.C resistance of conductor(km) | current rating | ||||||
in air(A) | direct in soil(A) | ||||||||||
cu | Al | cu | Al | cu | Al | ||||||
1×1.5 | 0.7 | 1.5 | 6 | <=12.1 | <=12.1 | 30 | 25 | 45 | 35 | ||
1×4 | 0.7 | 1.5 | 7 | <=7.41 | <=7.41 | 45 | 35 | 60 | 50 | ||
1×6 | 0.7 | 1.5 | 7 | <=3.08 | <=4.61 | 55 | 45 | 70 | 55 | ||
1×35 | 0.9 | 1.5 | 12 | <=0.524 | <=0.868 | 175 | 140 | 190 | 150 | ||
1×50 | 1 | 1.5 | 13 | <=0.387 | <=0.641 | 210 | 170 | 225 | 180 | ||
1×70 | 1.1 | 1.5 | 14 | <=0.268 | <=0.443 | 270 | 215 | 280 | 225 | ||
1×95 | 1.1 | 1.5 | 16 | <=0.193 | <=0.320 | 340 | 275 | 335 | 270 | ||
1×120 | 1.2 | 1.5 | 18 | <=0.153 | <=0.253 | 400 | 320 | 380 | 305 | ||
1×150 | 1.4 | 2 | 21 | <=0.124 | <=0.206 | 460 | 370 | 425 | 340 | ||
1×185 | 1.6 | 2 | 23 | <=0.0991 | <=0.164 | 530 | 415 | 480 | 375 | ||
1×240 | 1.7 | 2 | 25 | <=0.0754 | <=0.125 | 625 | 490 | 555 | 435 | ||
… | |||||||||||
3×1.5 | 0.7 | 1.5 | 10 | <=12.1 | <=12.1 | 25 | 25 | 30 | 30 | ||
3×2.5 | 0.7 | 1.5 | 11 | <=7.41 | <=12.1 | 30 | 25 | 35 | 30 | ||
3×4 | 0.7 | 1.5 | 12 | <=4.61 | <=7.41 | 40 | 30 | 50 | 40 | ||
… | |||||||||||
Attention: We can provide more info than above data, if needed.The above are just some examples. | |||||||||||
The desprition of 1kv copper xlpe insulated power cable
1.Max Long-time operating temperature of PVC insulated cable is 70°C,XLPE 90°C
2.Installing temperature of cable should not be less than 0°C
3.Max short-circuit temperature is:PVC not exceed 160°C,XLPE 250°C,Not more than5 Sec.
4.Permitting bending radius cable: Not less than 10 D times (D:external diameter of cable)
5.Perfect chemical stability, resistant against acids, alkali, grease and organic solvents, and flamer retardant.
PVC Insulation Electric Cable
TYPE | Description of Cable | Main Applications | |
CU core | AL core | ||
VV | VLV | Copper/Aluminium core,PVC insulated,PVC sheathed power cable | Non-armoured PVC cable are suited for laying indoors,In cable trench,On cable racks and in pipes. Unable bear external pressures and tensions. |
VY | VLY | Copper/Aluminium core,PVC insulated,PE sheathed power cable | |
VV22 | VLV22 | Copper/Aluminium core,PVC insulated,steel tape armored,PVC sheathed power cable | Steel-tape armoured PVC cables are suited for vertical burial.Can bear moderate positive pressures,Unable bear tension forces. |
VV23 | VLV23 | Copper/Aluminium core,PVC insulated,steel tape armored,PE sheathed power cable | |
VV32 | VLV32 | Copper/Aluminium core,PVC insulated,thin steel wire armored,PVC sheathed power cable | Thin steel wire armoured PVC cables are used in case of great difference of levels or vertical installation and Can do vertical burial.Can bear moderate positive pressures and tension forces. |
VV33 | VLV33 | Copper/Aluminium core,PVC insulated,thin steel wire armored,PE sheathed power cable | |
VV42 | VLV42 | Copper/Aluminium core,PVC insulated,thick steel wire armored,PVC sheathed power cable | Thick steel wire armoured PVC cables are suited for vertical installation and can be laid water or sea-bottom.Can bear greater positive pressures and tension forces. |
VV43 | VLV43 | Copper/Aluminium core,PVC insulated,thick steel wire armored,PE sheathed power cable |
XLPE Insulated electric cable
Type | Description | Application | |
Cu Core | Al Core | ||
YJV ZR-YJV | YJLV ZR-YJLV | Cu(Al)Core, XLPE Insulated, PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, PVC Sheathed flame- retardant Power Cable | Can be laid in indoor, outdoor, tunnels, cable channels, reinforced concrete pipelines and loose soil. Cable should not bear outer mechanic force, but can bear a certain tractional force. |
YJV22 ZR-YJV22 | YJLV22 ZR-YJLV22 | Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed flame- retardant Power Cable | Laid underground. Cable can bear outer mechanic force, but should not bear large tractional force. |
YJV32 ZR-YJV32 | YJLV32 ZR-YJLV32 | Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable | Laid in indoor, tunnels and mines. Cable can bear outer mechanic force and fairly large tractional force. |
YJV42 ZR-YJV42 | YJLV42 ZR-YJLV42 | Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable | Can be laid in vertical section, indoor, tunnels and mines. Cable can bear outer mechanic force and very large tractional force. |
Exhibition:
Certificates
Packaging & Shipping
All cable For exporting are well packed and protected by wooden drum or Wood and Steel Drum.The packing material is depended on the weight and size of cable.The good information, manufacture information, and the client's information is firmly printed on each size of drum.
After the well packed cable drums sent to Sea Port, they are loaded into 20 FT container or 40 FT container. All cable drum are firmly fixed by safety belt to make sure, no movement during the sea freight.
The size of the container is chosed according to weight of total loaded goods or as per the client's requirement.
Shipping Terms | DHL, UPS,FEDEX, TNT, or designated forwarder. |
Payment Terms | T/T, Western Union, or PayPal |
Freight cost | Prepay with goods payment or pay by collected. |
Packaging | Packed in bulk or as request |
Carton Measure | 49*33*23.5cm, 33*30*15cm, 30*30*18cm |