IEC 60502-1 Cable

IEC 60502-1 Cable
0.6/1kv, PVC Insulated Cables according to IEC 60502-1.
0.6/1kv, XLPE Insulated Cables according to IEC 60502-1.
Application: Building, Engineered, Railway, Plant construction, Shool, Hospital, Underground and so on.
Chat Now

Product Details


1.IEC60502-1 Cable


0.6/1kv, PVC Insulated Cables according to IEC 60502-1

Electric cable (684)Electric cable (680)Electric cable (686)


0.6/1kv, XLPE Insulated Cables according to IEC 60502-1

cable040Electric cable (156)05


2.Application: 

Building, Engineered, Railway, Plant construction, Shool, Hospital, Underground and so on.

These cables are used for electricity supply in low voltage installation system.

power cables


3.Specification

Voltage: 0.6/1KV

Cores: 1, 2, 3, 4, 5, 3+1, 4+1, 3+2

Conductor: Aluminum or Copper

Insulation: PVC/LSZH/XLPE

Armoured: SWA(Steel Wire Armoured) / STA(Steel Tape Armoured) or Non-Armoured
Section Area: 1.5mm2-300mm2
Packaging: Iron Or Wooden Drum


4.Cable size:

Single core(unarmoured)

Electric cable (517)


Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm^2

mm

mm

mm

mm

1x1.5

1.4

0.7

1.4

5.6

1x2.5

1.8

0.7

1.4

6.0

1x4

2.3

0.7

1.4

6.5

1x6

2.8

0.7

1.4

7.0

1x10

3.6

0.7

1.4

7.8

1x16

4.5

0.7

1.4

8.7

1x25

5.6

0.9

1.4

10.2

1x35

6.7

0.9

1.4

11.3

1x50

8.0

1

1.4

12.8

1x70

9.4

1.1

1.4

14.4

1x95

11.0

1.1

1.5

16.1

1x120

12.4

1.2

1.5

17.8

1x150

13.8

1.4

1.6

19.8

1x185

15.3

1.6

1.6

21.8

1x240

17.5

1.7

1.7

24.4

1x300

19.5

1.8

1.8

26.7

1x400

22.6

2

1.9

30.5

1x500

25.2

2.2

2.0

33.7

1x630

28.3

2.4

2.2

37.4

1x800

31.9

2.6

2.3

41.7

1x1000

35.7

2.8

2.4

46.2

 

Two cores(unarmoured)

Electric cable (374)

 

Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm^2

mm

mm

mm

mm

2x1.5

1.4

0.7

1.8

9.2

2x2.5

1.8

0.7

1.8

10.0

2x4

2.3

0.7

1.8

11.0

2x6

2.8

0.7

1.8

12.0

2x10

3.6

0.7

1.8

13.6

2x16

4.5

0.7

1.8

15.4

2x25

5.6

0.9

1.8

18.4

2x35

6.7

0.9

1.8

20.6

2x50

8.0

1

1.8

23.6

2x70

9.4

1.1

1.8

26.8

2x95

11.0

1.1

1.9

30.2

2x120

12.4

1.2

2.0

33.7

2x150

13.8

1.4

2.2

37.5

2x185

15.3

1.6

2.3

41.6

2x240

17.5

1.7

2.5

46.7

2x300

19.5

1.8

2.6

51.4

2x400

22.6

2

2.9

58.9

 

Three cores(unarmoured)

Electric cable (252)

 

Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm^2

mm

mm

mm

mm

3x1.5

1.4

0.7

1.8

9.6

3x2.5

1.8

0.7

1.8

10.5

3x4

2.3

0.7

1.8

11.6

3x6

2.8

0.7

1.8

12.6

3x10

3.6

0.7

1.8

14.4

3x16

4.5

0.7

1.8

16.3

3x25

5.6

0.9

1.8

19.5

3x35

6.7

0.9

1.8

21.9

3x50

8.0

1

1.8

25.1

3x70

9.4

1.1

1.9

28.7

3x95

11.0

1.1

2.0

32.4

3x120

12.4

1.2

2.1

36.1

3x150

13.8

1.4

2.3

40.3

3x185

15.3

1.6

2.4

44.6

3x240

17.5

1.7

2.6

50.2

3x300

19.5

1.8

2.7

55.2

3x400

22.6

2

3.0

63.3

 

Three cores+1(unarmoured)

Electric cable (389)

 

Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm^2

(3)mm

(1)mm

(3)mm

(1)mm

mm

mm

3x 16/10

4.5

3.6

0.7

0.7

1.8

17.5

3x 25/16

5.6

4.5

0.9

0.7

1.8

21.2

3x 35/16

6.7

4.5

0.9

0.7

1.8

23.8

3x 50/25

8

5.6

1

0.9

1.8

27.5

3x 70/35

9.4

6.7

1.1

0.9

2.0

31.7

3x 95/50

11

8

1.1

1

2.1

35.8

3x120/70

12.4

9.4

1.2

1.1

2.3

39.9

3x150/70

13.8

9.4

1.4

1.1

2.4

44.6

3x185/95

15.3

11

1.6

1.1

2.6

49.5

3x240/120

17.5

12.4

1.7

1.2

2.8

55.7

3x300/150

19.5

13.8

1.8

1.4

3.0

61.4

3x400/185

22.6

15.3

2

1.6

3.2

70.4


Four cores(unarmoured)

Electric cable (481)

 

Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm^2

mm

mm

mm

mm

4x1.5

1.4

0.7

1.8

10.4

4x2.5

1.8

0.7

1.8

11.3

4x4

2.3

0.7

1.8

12.5

4x6

2.8

0.7

1.8

13.7

4x10

3.6

0.7

1.8

15.7

4x16

4.5

0.7

1.8

17.8

4x25

5.6

0.9

1.8

21.5

4x35

6.7

0.9

1.8

24.1

4x50

8.0

1

1.8

27.8

4x70

9.4

1.1

2.0

32.0

4x95

11.0

1.1

2.1

36.1

4x120

12.4

1.2

2.3

40.2

4x150

13.8

1.4

2.4

44.9

4x185

15.3

1.6

2.6

49.8

4x240

17.5

1.7

2.8

56.0

4x300

19.5

1.8

3.0

61.7

4x400

22.6

2

3.2

70.7

 

Multi-cores(unarmoured)

Electric cable (434)

 

Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm^2

mm

mm

mm

mm

5x1.5

1.4

0.7

1.8

11.2

7x1.5

1.4

0.7

1.8

12.0

10x1.5

1.4

0.7

1.8

14.8

12x1.5

1.4

0.7

1.8

15.2

14x1.5

1.4

0.7

1.8

16.0

19x1.5

1.4

0.7

1.8

17.6

21x1.5

1.4

0.7

1.8

18.4

24x1.5

1.4

0.7

1.8

20.4

30x1.5

1.4

0.7

1.8

21.6

40x1.5

1.4

0.7

1.8

26.0

48x1.5

1.4

0.7

1.8

26.4

61x1.5

1.4

0.7

1.9

29.0

5x2.5

1.8

0.7

1.8

12.2

7x2.5

1.8

0.7

1.8

13.2

10x2.5

1.8

0.7

1.8

16.4

12x2.5

1.8

0.7

1.8

16.9

14x2.5

1.8

0.7

1.8

17.7

19x2.5

1.8

0.7

1.8

19.6

21x2.5

1.8

0.7

1.8

20.6

24x2.5

1.8

0.7

1.8

22.8

30x2.5

1.8

0.7

1.8

24.1

40x2.5

1.8

0.7

1.9

29.4

48x2.5

1.8

0.7

1.9

29.9

61x2.5

1.8

0.7

2.0

32.8

Inquiry