1.Application
1)XLPE insulated power cable has a number of advantages compared with paper insulated and PVC insulate cables.
2)XLPE cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level.
3) It can be applied in high temperature of 90 degree for a long time.
4)Flame-retardant and non-flame-retardant XLPE cables can be manufactured by three kinds of technological processes: peroxidation, silanization and irradiation.
5)The flame-retardant cable covers three classes of A, B, C and low-smoke low-halogen, low-smoke non-halogen cables.
2.Standard
Our XLPE cable are produced according to IEC 60502, IEC60332, and IEC 60754, even some of our indexes are superior to the above international IEC standards. Meanwhile, we can produce cables according to other standards and can design the XLPE cables with some certain special properties according to customers' requirements.
XLPE cable can be applied in high temperature for a long time and has bigger current capacity. In the same environment conditions, compared with paper insulated and PVC insulated cables, XLPE cable can lessen the cross section by 1 or 2 grades.
3.Specification
We can make it according to: IEC,BS,VDE,AS/NZS,ICEA,JIS and so on;
1)0.6/1kV, Single Core, Cu or Al/XLPE/PVC Power Cable;
0.6/1kV, Single Core, Cu or Al/XLPE/PVC/AWA/PVC Power Cable
Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Thickness of PVC Inner Sheath | Diameter of Al Wires | Nominal Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight | |||||
Cu Conductor | Al Conductor | |||||||||||
AWA | AWA | UnAr | AWA | UnAr | AWA | UnAr | AWA | UnAr | AWA | |||
mm2 | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km |
1.5 | 1.6 | 0.7 | - | - | 1.4 | - | 5.7 | - | 44 | - | - | - |
2.5 | 2.0 | 0.7 | - | - | 1.4 | - | 6.2 | - | 57 | - | - | - |
4 | 2.6 | 0.7 | - | - | 1.4 | - | 6.7 | - | 74 | - | - | - |
6 | 3.1 | 0.7 | - | - | 1.4 | - | 7.3 | - | 96 | - | - | - |
10 | 3.8 | 0.7 | 1.0 | 0.8 | 1.4 | 1.4 | 7.9 | 12.4 | 134 | 235 | 74 | 175 |
16 | 4.8 | 0.7 | 1.0 | 0.8 | 1.4 | 1.4 | 8.9 | 13.4 | 196 | 307 | 99 | 209 |
25 | 6.0 | 0.9 | 1.0 | 0.8 | 1.4 | 1.4 | 10.6 | 15.1 | 289 | 417 | 139 | 267 |
35 | 7.1 | 0.9 | 1.0 | 0.8 | 1.4 | 1.4 | 11.7 | 16.2 | 382 | 522 | 172 | 309 |
50 | 8.4 | 1.0 | 1.0 | 1.25 | 1.4 | 1.5 | 13.2 | 18.7 | 503 | 710 | 220 | 427 |
70 | 10.0 | 1.1 | 1.0 | 1.25 | 1.4 | 1.5 | 15.0 | 20.5 | 702 | 936 | 293 | 522 |
95 | 11.7 | 1.1 | 1.0 | 1.25 | 1.5 | 1.5 | 16.8 | 22.4 | 950 | 1209 | 384 | 638 |
120 | 13.3 | 1.2 | 1.0 | 1.6 | 1.5 | 1.6 | 18.6 | 25.1 | 1186 | 1531 | 469 | 806 |
150 | 14.5 | 1.4 | 1.0 | 1.6 | 1.5 | 1.6 | 20.4 | 26.7 | 1458 | 1820 | 567 | 923 |
185 | 16.4 | 1.6 | 1.0 | 1.6 | 1.5 | 1.7 | 22.7 | 29.2 | 1810 | 2219 | 698 | 1105 |
240 | 18.7 | 1.7 | 1.0 | 1.6 | 1.6 | 1.8 | 25.4 | 31.9 | 2348 | 2802 | 889 | 1335 |
300 | 20.4 | 1.8 | 1.0 | 1.6 | 1.7 | 1.8 | 27.4 | 33.7 | 2917 | 3393 | 1091 | 1568 |
400 | 23.2 | 2.0 | 1.2 | 2.0 | 1.8 | 2.0 | 30.9 | 38.5 | 3713 | 4377 | 1379 | 2043 |
500 | 26.4 | 2.2 | 1.2 | 2.0 | 1.9 | 2.1 | 34.7 | 42.3 | 4770 | 5512 | 1767 | 2510 |
630 | 30.0 | 2.4 | 1.2 | 2.0 | 2.1 | 2.2 | 39.1 | 46.5 | 6105 | 6914 | 2248 | 3058 |
800 | 34.0 | 2.6 | 1.4 | 2.5 | 2.2 | 2.4 | 43.6 | 52.6 | 7893 | 9008 | 2867 | 3981 |
1000 | 41.4 | 2.8 | 1.4 | 2.5 | 2.3 | 2.5 | 51.6 | 60.8 | 10189 | 11524 | 3690 | 5025 |
4. Nominal Cross-sectional Areas
1.5 mm2 , 2.5 mm2 ,4 mm2 , 6 mm2 , 10 mm2 , 16 mm2 ,25 mm2 , 35 mm2 , 50 mm2 ,70 mm2 , 95 mm2 ,120 mm2 ,150 mm2 ,185 mm2 ,240 mm2 ,300 mm2 400 mm2 500 mm2 630 mm2 800 mm2
5. Production Range
single core cable from 1.5 mm2 to 800 mm2,muli-core cable from 1.5 mm2 to 400 mm2
6. Operating Characteristics
Rated power-frequency voltage u0/u:0.6/1 KV
Max permissible continuous operating temperature of conductor 70
Max short-circuit temperature of the conductor shall not exceed (Max 5 seconds duration): cross-section of conductor 300 mm2
The ambient temperature under installations should not be below 0
The bending radius of single core cable should not be less than 20 times of the cable diameter ,the bending radius of multi-core cable should not be less than 15 times of the cable diameter.
We also can manufacture many other specifications, if you have interest, welcome your enquiry! Everything we do is trying to make your business more successful.
300/500V 450/750V electrical wire | AAC conductor |
600/1000V PVC insulated cable | AAAC conductor |
600/1000V XLPE insulated cable | ACSR conductor |
1.8/3KV to 26/35KV power cable | OPGW |
Armored underground cable | ABC cable |
Control cable and instrumentation cables | Rubber cable |
Certificates
Strict Quality Test
Packaging & Shipping
Why choose us
1.21 years manufacturing experience
2.Professional international trade team
3.Delivery on time
4.Factory low price and high quality based on advanced technology and high work efficiency